YNAO OpenIR  > 应用天文研究组
1.2m望远镜自适应光学系统中激光导引星聚焦非等晕性
其他题名Focus anisoplanatism for 1.2 m telescope laser guide stars in adaptive optics system
周钰; 熊耀恒
发表期刊强激光与粒子束
2008-04
卷号20期号:4页码:529-532
分类号P111.2
产权排序第1完成单位
收录类别EI ; CSCD
关键词聚焦非等晕性 多重导星 信标位置测量误差 圆锥倾斜误差
摘要分析了云南天文台1.2 m望远镜61单元自适应光学系统上如果配置激光导引星,由信标上方以及信标下方采样不完整性造成的聚焦非等晕性误差大小。为了减小聚焦非等晕性误差,可以采用投射多重信标方法。同时讨论了多重信标方法造成的信标位置测量误差和圆锥倾斜误差两种额外误差,理论分析并数值模拟了当投射2~5颗钠导星和瑞利导星时其误差大小。结果表明:随着导星高度以及导星数的增加,该方法可以有效地减小聚焦非等晕性误差,对于钠导星其误差小于1 rad2。
其他摘要A precise simulation the focus anisoplanatism error of Yunnan observatory 1.2 m 61-element laser guide star adaptive optics system, which caused by laser beacon at a finite range travels a different path than does the light from natural star at a infinite range. This error can be eliminated by use of laser guide stars. However, there are two sources of error limit multiple beacon adaptive optical system, beacon position measurement error and conic tilt error. Analysis the two errors when project two to five laser guide stars. The result showed that with the increase of high and number of laser beam, especially the focus anisoplanatism of Na laser guide stars could reduced to 1 rad2.
语种中文
学科领域天文学
文章类型期刊论文
ISSN1001-4322
归档日期2008-06-24
CSCD记录号CSCD:3268391
引用统计
被引频次:4[CSCD]   [CSCD记录]
文献类型期刊论文
条目标识符http://ir.ynao.ac.cn/handle/114a53/7500
专题应用天文研究组
推荐引用方式
GB/T 7714
周钰,熊耀恒. 1.2m望远镜自适应光学系统中激光导引星聚焦非等晕性[J]. 强激光与粒子束,2008,20(4):529-532.
APA 周钰,&熊耀恒.(2008).1.2m望远镜自适应光学系统中激光导引星聚焦非等晕性.强激光与粒子束,20(4),529-532.
MLA 周钰,et al."1.2m望远镜自适应光学系统中激光导引星聚焦非等晕性".强激光与粒子束 20.4(2008):529-532.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
1_2m望远镜自适应光学系统中激光导引星(337KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[周钰]的文章
[熊耀恒]的文章
百度学术
百度学术中相似的文章
[周钰]的文章
[熊耀恒]的文章
必应学术
必应学术中相似的文章
[周钰]的文章
[熊耀恒]的文章
相关权益政策
暂无数据
收藏/分享
文件名: 1_2m望远镜自适应光学系统中激光导引星聚焦非等晕性_周钰.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。